Review



half area 96 well microplate  (Greiner Bio)


Bioz Verified Symbol Greiner Bio is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    Greiner Bio half area 96 well microplate
    Half Area 96 Well Microplate, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 95/100, based on 95 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Microplate+96+Well+Ps+Half+Area+White/bio_rxiv__64898__2026__11__03__763784-406-6-9
    Average 95 stars, based on 95 article reviews
    half area 96 well microplate - by Bioz Stars, 2026-11
    95/100 stars

    Images

    Related Articles

    Suspension:

    Article Title: Development of a BRET based chloride biosensor for high throughput screening of KCC2 modulators.
    Article Snippet: HEK Jump-In KCC2 cells transiently expressing the Superclomeleon biosensor were resuspended and plated in black poly-D-lysine-coated 96-well microplates (Greiner, cat 655946), at 5 × 105 cells/well with 1 ng/mL doxycycline.

    Article Title: Regulation of long-range BMP gradients and embryonic polarity by propagation of local calcium-firing activity
    Article Snippet: In total, 40 μl of plating suspension was transferred to each well of non-cell-adhesive sterile round-bottomed 96-well microplates (Greiner 650970) as required.

    Article Title: Compounds for the treatment of respiratory diseases
    Article Snippet: Generally, capture antibodies were initially diluted to the recommended concentrations using PBS buffer, and then used to coat the wells of 96-well microplates (Greiner, #655061) by adding 50 μL/well and incubated overnight at room temperature.

    Article Title: Less neutralization evasion of SARS-CoV-2 BA.2.86 than XBB sublineages and CH.1.1.
    Article Snippet: Briefly, VeroE6 cells per well were seeded in Greiner Bio-oneTM 96- well microplates.

    Article Title: Cobalt modulates methanol turnover of the alcohol dehydrogenase in Desulfofundulus kuznetsovii strain TPOSR.
    Article Snippet: Kinetic assays to study the methanol oxidation of TPOSR Adh1 were carried out in 50 mM BTP buffer, at 55°C, using 96-well microplates (Greiner, 675101).

    Article Title: Binding of the erlin1/2 complex to the third intralumenal loop of IP 3 R1 triggers its ubiquitin-proteasomal degradation
    Article Snippet: Cells were subcultured ∼24 h later and transferred either to poly-D-lysine–treated 96-well microplates (Greiner) to measure free cytosolic Ca 2+ or to new 6-well plates for analysis of IP 3 R1HA expression ∼24 h later.

    Article Title: Less neutralization evasion of SARS-CoV-2 BA.2.86 than XBB sublineages and CH.1.1
    Article Snippet: Briefly, VeroE6 cells per well were seeded in Greiner Bio-oneTM 96-well microplates.

    Sterility:

    Article Title: Development of a BRET based chloride biosensor for high throughput screening of KCC2 modulators.
    Article Snippet: HEK Jump-In KCC2 cells transiently expressing the Superclomeleon biosensor were resuspended and plated in black poly-D-lysine-coated 96-well microplates (Greiner, cat 655946), at 5 × 105 cells/well with 1 ng/mL doxycycline.

    Article Title: Regulation of long-range BMP gradients and embryonic polarity by propagation of local calcium-firing activity
    Article Snippet: In total, 40 μl of plating suspension was transferred to each well of non-cell-adhesive sterile round-bottomed 96-well microplates (Greiner 650970) as required.

    Article Title: Compounds for the treatment of respiratory diseases
    Article Snippet: Generally, capture antibodies were initially diluted to the recommended concentrations using PBS buffer, and then used to coat the wells of 96-well microplates (Greiner, #655061) by adding 50 μL/well and incubated overnight at room temperature.

    Article Title: Less neutralization evasion of SARS-CoV-2 BA.2.86 than XBB sublineages and CH.1.1.
    Article Snippet: Briefly, VeroE6 cells per well were seeded in Greiner Bio-oneTM 96- well microplates.

    Article Title: Cobalt modulates methanol turnover of the alcohol dehydrogenase in Desulfofundulus kuznetsovii strain TPOSR.
    Article Snippet: Kinetic assays to study the methanol oxidation of TPOSR Adh1 were carried out in 50 mM BTP buffer, at 55°C, using 96-well microplates (Greiner, 675101).

    Article Title: Binding of the erlin1/2 complex to the third intralumenal loop of IP 3 R1 triggers its ubiquitin-proteasomal degradation
    Article Snippet: Cells were subcultured ∼24 h later and transferred either to poly-D-lysine–treated 96-well microplates (Greiner) to measure free cytosolic Ca 2+ or to new 6-well plates for analysis of IP 3 R1HA expression ∼24 h later.

    Article Title: Less neutralization evasion of SARS-CoV-2 BA.2.86 than XBB sublineages and CH.1.1
    Article Snippet: Briefly, VeroE6 cells per well were seeded in Greiner Bio-oneTM 96-well microplates.



    Similar Products

    96
    Sartorius AG incucyte imagelock 96 well plates
    Incucyte Imagelock 96 Well Plates, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Incucyte+Imagelock+96-well+Microplate/bio_rxiv__64898__2026__11__05__764503-119-19-23
    Average 96 stars, based on 1 article reviews
    incucyte imagelock 96 well plates - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    95
    Greiner Bio half area 96 well microplate
    Half Area 96 Well Microplate, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Microplate+96+Well+Ps+Half+Area+White/bio_rxiv__64898__2026__11__03__763784-406-6-9
    Average 95 stars, based on 1 article reviews
    half area 96 well microplate - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    96
    Greiner Bio high binding 96 well polystyrene microplates
    (A) Positive control demonstrating that post-iRSVF protein (0.5 µg/well) is coated onto the <t>high-binding</t> immunoassay microplates. Two tryptic RSVF peptides were measured, with a BSA peptide was presented as a loading control. (B) Negative control demonstrating the lack of non-specific binding of NISTmAb 8671 monoclonal antibody (1 µg/well) to the microplates coated with PBS and blocked with BSA (C) ProWiSe assays revealed that NISTmAb (1 µg/well) was enriched 640-fold with post-iRSVF protein (0.5 µg/well) relative to the negative control. (D) As an additional positive control, SARS-CoV-2 RBD protein (0.5 µg/well) enriched IgG1 antibodies from a pool of convalescent human sera (20 µL/well), as previously reported . NISTmAb, an IgG1 antibody, shares a unique tryptic peptide, GPSVFPLAPSSK, with endogenous human IgG1. (E) RSV-specific polyclonal antibodies were enriched from 80 maternal sera samples using an RSV post-iRSVF antigen, with three matched no-antigen negative controls. (F) For comparison, SARS-CoV-2-specific polyclonal antibodies were enriched with an RBD antigen from 10 PCR-confirmed convalescent plasma samples (+) and 5 pre-pandemic negative plasma (-). All IA enrichments and trypsin digestions (A-F) were completed onto a single microplate, and nanoLC-MS/MS with label-free MS1 quantification were used for analysis. *indicated statistically significant isotypes or subclasses determined using Bonferroni-adjusted 1-tail Mann-Whitney U test P -values < 0.0063. LOD levels were calculated in positive samples based on detectable peaks of the light endogenous peptides with a signal-to-noise ratio>3 for the combined MS1 intensity of a precursor and M+1 forms. Concentrations below LOD were adjusted to the LOD levels. PBS group levels below LOD are presented to demonstrate the variability of non-specific binding for all isotypes. PBS, no-antigen negative control with PBS buffer; RSVF, postfusion RSVF expressed in baculovirus-insect cells; RBD (+), Receptor binding domain of the spike glycoprotein SARS-CoV-2; RBD(-), no-antigen negative control with PBS buffer.
    High Binding 96 Well Polystyrene Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Microplate+96+Well+Ps+F-Bottom+(Chimney/bio_rxiv__64898__2026__11__03__764056-40-0-5
    Average 96 stars, based on 1 article reviews
    high binding 96 well polystyrene microplates - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    99
    Greiner Bio matrigel coated clear bottom 96 well plates
    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in <t>96-well</t> plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.
    Matrigel Coated Clear Bottom 96 Well Plates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Cell+Culture+Microplate+96+Well+Ps+F-Bottom/bio_rxiv__64898__2026__10__31__763029-49-6-10
    Average 99 stars, based on 1 article reviews
    matrigel coated clear bottom 96 well plates - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    96
    Sartorius AG imagelock 96 well plates
    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in <t>96-well</t> plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.
    Imagelock 96 Well Plates, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Incucyte+Imagelock+96-well+Microplate/pm42970682-358-9-12
    Average 96 stars, based on 1 article reviews
    imagelock 96 well plates - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    94
    Greiner Bio 96 well microplates
    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in <t>96-well</t> plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.
    96 Well Microplates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Uv-Star+Microplate+96+Well+Half+Area/bio_rxiv__64898__2026__10__31__763289-347-7-9
    Average 94 stars, based on 1 article reviews
    96 well microplates - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    96
    Sartorius AG 96 well imagelock plates
    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in <t>96-well</t> plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.
    96 Well Imagelock Plates, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Incucyte+Imagelock+96-well+Microplate/pm42966774-81-8-12
    Average 96 stars, based on 1 article reviews
    96 well imagelock plates - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    93
    Greiner Bio μclear medium
    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in <t>96-well</t> plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.
    μclear Medium, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Microplate+96+Well+Ps+Half+Area+%CE%9Cclear/bio_rxiv__64898__2026__10__29__762820-168-36-41
    Average 93 stars, based on 1 article reviews
    μclear medium - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    96
    Sartorius AG incucyte imagelock plates
    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in <t>96-well</t> plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.
    Incucyte Imagelock Plates, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Incucyte+Imagelock+96-well+Microplate/pm42963391-425-15-18
    Average 96 stars, based on 1 article reviews
    incucyte imagelock plates - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    96
    Greiner Bio 96 well plates
    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in <t>96-well</t> plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.
    96 Well Plates, supplied by Greiner Bio, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/96-well+microplates/Microplate+96+Well+Pp+F-Bottom/bio_rxiv__64898__2026__10__28__762652-376-5-7
    Average 96 stars, based on 1 article reviews
    96 well plates - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    Image Search Results


    (A) Positive control demonstrating that post-iRSVF protein (0.5 µg/well) is coated onto the high-binding immunoassay microplates. Two tryptic RSVF peptides were measured, with a BSA peptide was presented as a loading control. (B) Negative control demonstrating the lack of non-specific binding of NISTmAb 8671 monoclonal antibody (1 µg/well) to the microplates coated with PBS and blocked with BSA (C) ProWiSe assays revealed that NISTmAb (1 µg/well) was enriched 640-fold with post-iRSVF protein (0.5 µg/well) relative to the negative control. (D) As an additional positive control, SARS-CoV-2 RBD protein (0.5 µg/well) enriched IgG1 antibodies from a pool of convalescent human sera (20 µL/well), as previously reported . NISTmAb, an IgG1 antibody, shares a unique tryptic peptide, GPSVFPLAPSSK, with endogenous human IgG1. (E) RSV-specific polyclonal antibodies were enriched from 80 maternal sera samples using an RSV post-iRSVF antigen, with three matched no-antigen negative controls. (F) For comparison, SARS-CoV-2-specific polyclonal antibodies were enriched with an RBD antigen from 10 PCR-confirmed convalescent plasma samples (+) and 5 pre-pandemic negative plasma (-). All IA enrichments and trypsin digestions (A-F) were completed onto a single microplate, and nanoLC-MS/MS with label-free MS1 quantification were used for analysis. *indicated statistically significant isotypes or subclasses determined using Bonferroni-adjusted 1-tail Mann-Whitney U test P -values < 0.0063. LOD levels were calculated in positive samples based on detectable peaks of the light endogenous peptides with a signal-to-noise ratio>3 for the combined MS1 intensity of a precursor and M+1 forms. Concentrations below LOD were adjusted to the LOD levels. PBS group levels below LOD are presented to demonstrate the variability of non-specific binding for all isotypes. PBS, no-antigen negative control with PBS buffer; RSVF, postfusion RSVF expressed in baculovirus-insect cells; RBD (+), Receptor binding domain of the spike glycoprotein SARS-CoV-2; RBD(-), no-antigen negative control with PBS buffer.

    Journal: bioRxiv

    Article Title: Proteome-Wide Serology Identifies Secreted IgD against RSV Fusion Glycoprotein as a Signature of Broadly Elevated Antibody Response

    doi: 10.64898/2026.11.03.764056

    Figure Lengend Snippet: (A) Positive control demonstrating that post-iRSVF protein (0.5 µg/well) is coated onto the high-binding immunoassay microplates. Two tryptic RSVF peptides were measured, with a BSA peptide was presented as a loading control. (B) Negative control demonstrating the lack of non-specific binding of NISTmAb 8671 monoclonal antibody (1 µg/well) to the microplates coated with PBS and blocked with BSA (C) ProWiSe assays revealed that NISTmAb (1 µg/well) was enriched 640-fold with post-iRSVF protein (0.5 µg/well) relative to the negative control. (D) As an additional positive control, SARS-CoV-2 RBD protein (0.5 µg/well) enriched IgG1 antibodies from a pool of convalescent human sera (20 µL/well), as previously reported . NISTmAb, an IgG1 antibody, shares a unique tryptic peptide, GPSVFPLAPSSK, with endogenous human IgG1. (E) RSV-specific polyclonal antibodies were enriched from 80 maternal sera samples using an RSV post-iRSVF antigen, with three matched no-antigen negative controls. (F) For comparison, SARS-CoV-2-specific polyclonal antibodies were enriched with an RBD antigen from 10 PCR-confirmed convalescent plasma samples (+) and 5 pre-pandemic negative plasma (-). All IA enrichments and trypsin digestions (A-F) were completed onto a single microplate, and nanoLC-MS/MS with label-free MS1 quantification were used for analysis. *indicated statistically significant isotypes or subclasses determined using Bonferroni-adjusted 1-tail Mann-Whitney U test P -values < 0.0063. LOD levels were calculated in positive samples based on detectable peaks of the light endogenous peptides with a signal-to-noise ratio>3 for the combined MS1 intensity of a precursor and M+1 forms. Concentrations below LOD were adjusted to the LOD levels. PBS group levels below LOD are presented to demonstrate the variability of non-specific binding for all isotypes. PBS, no-antigen negative control with PBS buffer; RSVF, postfusion RSVF expressed in baculovirus-insect cells; RBD (+), Receptor binding domain of the spike glycoprotein SARS-CoV-2; RBD(-), no-antigen negative control with PBS buffer.

    Article Snippet: High-binding 96-well polystyrene microplates (#655074, Greiner Bio-One, Monroe, NC) were coated overnight with recombinant antigen proteins in PBS: the initial experiments with untargeted DDA MS utilized 0.5 μg antigen/well, while the subsequent experiments with the targeted SRM and untargeted DIA measurements included 0.3 μg antigen/well.

    Techniques: Positive Control, Binding Assay, Control, Negative Control, Nonspecific Binding, Comparison, Clinical Proteomics, Tandem Mass Spectroscopy, Analysis, MANN-WHITNEY

    a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in 96-well plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.

    Journal: bioRxiv

    Article Title: CardioShift: Resolving cell-to-cell functional heterogeneity in hiPSC-derived cardiomyocytes from high-throughput single-cell imaging

    doi: 10.64898/2026.10.31.763029

    Figure Lengend Snippet: a , hiPSC-CMs carrying MYH7 R403L and the isogenic control (MYH7 ISO) were plated as monolayers in 96-well plates, matured for 20 days in maturation medium and exposed for 7 days to control medium (BSA vehicle), palmitate, oleate, or their combination. Cells were imaged on a Kinetic Image Cytometer under 1 Hz field pacing in two imaging sessions in the same wells. b , In session 1, cells were stained with Hoechst and Cal-520 and Ca 2+ transients were recorded for 10 s at 33 frames per second. In session 2, cells were stained with Hoechst, BODIPY 493/503 and WGA, and contraction was recorded for 5 s at 70 frames per second. Cells were segmented automatically from the nuclear and cytoplasmic signals in session 1 and as a circle around each nucleus in session 2. Scale bars, 50 µm. c , Traces of eight electrically responsive cells from one well per session (first 5 s shown). d , Definition of the functional parameters. Left, one Ca 2+ transient of a control MYH7 R403L cell, selected as the cell whose parameters were closest to the control median. Peak amplitude is the peak height of the trace. Rise time is the time from 10% of peak amplitude to the peak, and decay time the time from the peak to 20% of peak amplitude (80% recovery). CTD 50 and CTD 90 are the Ca 2+ transient durations at 50% and 90% recovery, measured between the upstroke and downstroke crossings at 50% and 10% of peak amplitude. Right, contraction trace of a control MYH7 ISO cell, averaged over four beats aligned on their peaks. Rise and decay times are defined as for Ca 2+ but at 20% of peak amplitude. Dashed lines show the reference levels as a percentage of peak amplitude. Time is shown relative to the peak. Parameters were extracted from every electrically responsive cell after quality control for pacing fidelity and beat count.

    Article Snippet: After expansion, hiPSC-CMs were replated onto Matrigel-coated clear-bottom 96-well plates (Greiner Bio-One, 655090) at 1.0 × 10 5 cells per well to form confluent monolayers.

    Techniques: Control, 96 Well Plates, Cytometry, Imaging, Staining, Functional Assay, QC/EQA/Proficiency, Single Cell